Anaesthesia Machine MJ-560B5 MJ-560B5 Anesthesia Machine, with its ergonomic design, integratedstructure, easy for transport. The microcomputer-controlled Ventilator adopts imported sensors and other components Its scientific and proper design as well as rigorous production process. Comprehensive monitoring and alarm, high-precision vaporizer, three gas source inputs, sensitive flow control system, highly integrated breathing circuit, with multiple modern technologies applied, the Anesthesia Machine is both outstanding it performance and versatile in functions.
COMPREHENSIVE MONITORING & INTELLIGENT SYSTEM Large screen high-definition 10.4 " TFT wide-angle color LCD Touch Screen display Extra-large workbench with larger capacity drawers Comprehensive waveform information display Timely alarm function and self-check function to avoid various risks caused by surgery Intelligent anesthesia information management system
PRECISION CONTROL SYSTEM Supports input of 3 gas sources: Oxygen, Nitrous oxide and Air Equipped with 5 tubes high-precision flow meters, to ensure precise regulation of Oxygen, Nitrous oxide, and Air O2-N2O Linkage and N2O Stopper, to ensure the minimum oxygen concentration and automatic protection of N2O safety HIGH-PRECISION VAPORIZER Vaporizer can support low flow anesthesia as low as 0.2L/min and large flow anesthesia up to 15L/min. Accurate output of concentrations under varying conditions of pressure, flow and temperature. 4 Kinds of Vaporizer for Choice: Halothane, Enflurane, Isoflurane and Sevoflurane Fill-in type: Pouring
INTEGRATED BREATHING CIRCUIT Integrated breathing circuit with APL valve, excellent tightness and safety. Made of special materials, resistant to corrosion and high temperature. Compact structure, no external pipelines, good mechanical compliance. Impeller sampling is used at the exhalation end to avoid inaccurate monitoring of tidal volume due to water vapor condensation. Drive bellows is not required to repalce when operating pediatric anesthesia. Large volume of CO2 canister, single tank structure for more convenient in assembly.
TECHNICAL PARAMETERS PART OF ANESTHESIA MACHINE Main Body High-strength engineering plastic rack, light, beautiful and corrosion resistant
Scope of Application: Adult, Child
Gas Source O2: 0.28~0.6MPa, N2O: 0.28~0.6MPa, Air
Flow Meter O2: 0.05~1.0L/min,1.1~10L/min N2O: 0.05~1.0L/min,1.1~10L/min Air: 0.1~10L/min
O2-N2O Linkage and N2O Stopper When using nitrous oxide, oxygen concentration>25%; When the oxygen pressure<0.16±0.02Kpa, the flow of nitrous oxide would be cut off.
Flow Rate of Rapid Oxygen Supply 25~75L/min
Low Oxygen Pressure Alarm There will be sound alarm when the oxygen pressure < 0.2MPa
Vaporizer It has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%. Among Halothane,Enflurane, Isoflurane and Sevoflurane, two can be chosen for application as required by the customer.
Respiratory Circuit Working mode: All-close, Semi-close, Semi-open APL: ≤12.5 kPa
Respiratory Bellows Bellows for adults and children Tidal volume range: 0~1500 ml
PART OF VENTILATOR Display Mode High-definition 10.4"TFT color LCD touch screen display, easy and convenient operation
Ventilation Mode VCV,PCV,SIMV,MANUAL
Ventilation Function PEEP,SIGH, IRV,Inspiratory platform, Standby
Ventilation Parameters Tidal volume:20~1500 ml Rate:2~120 bpm SIMV rate:2~20 bpm I:E:4:1~1:8 Inspiratory trigger pressure: -10~20 cmH2O PEEP:0~25 cmH2O Pressure range:5~60 cmH2O SIGH:1.5 times the inspiratory time/ 60~120 times breath Inspiratoryplatform: 0~50% Pressure control:3~60 cmH2O Pressure slope:1~10 gear
Parameters For Ventilation Monitoring VI tidal volume, VE tidal volume, Minute Ventilation volume, IPPV rate, SIMV rate, total respiratory rate, autonomous breathing rate, I/E, peak pressure of airway, average pressure, PEEP, Inspiratory trigger pressure, inspiratory platform, oxygen concentration, battery capacity , pressure - time waveform, flow rate - time waveform, flow-volume loop, pressure -volume loop
Security Alarm System Oxygen Concentration Alarm: Upper limit setting range:21%~99%,Low limit setting range:15%~80% Airway Pressure Alarm: Upper limit setting range:5~60 cmH2O,Low limit setting range:0~50cmH2O Per-minute Ventilation Volume Alarm: Upper limit setting range:1~30L/min, Low limit setting range: 0~29L/min Tidal Volume alarm: Upper limit setting range:100~2000ml,Low limit setting range 0~1800ml Sustained High Pressure Alarm: It will give alarm when stress have consistently been higher than 25 cmH2O for 15s. Suffocation Alarm: It will give alarm when stress have consistently been higher than 10 cmH2O and tidal volume is less than 120ml for 15s. Tube Escape Alarm: It will give alarm when stress have consistently been less than 2cmH2O for 15s. Low Battery Level Alarm: It will give alarm when battery level is less than 14±0.5V
Power Supply AC 100~240V,50/60Hz Built-in Li Battery (Work at least for 6-8 hours with battery)
Options Mechanical Arms Bracket for Patient Monitor ETCO2 monitoring